Skip to content

DDP400 Top Fan AC/DC Power Supplies

The DDP400 series of single output AC/DC power supplies includes this top-fan model and is available in standard voltages of 12, 24, 36 and 48 VDC, with auxiliary 12V fan and +5V stand-by outputs.

Key features

  • 94% efficient
  • 400 W power output (440 W peak)
  • Wide input voltage range (90 – 264 VAC)
  • 12, 24, 36, & 48V standard output variants
  • +5V stand-by and 12V auxiliary outputs
  • 4000m altitude operation
  • Remote enable & DC power good signal
  • Variable fan speed for quiet operation:
    • fan off < 50 W
  • Very low stand-by consumption < 0.5 W
  • Active PFC, EN61000-3-2 compliant:
    • class C, > 50 W load

Applications

  • Industrial & process controls
  • Video wall displays & entertainment equipment
  • Telecommunications
  • Laboratory equipment
  • Test & measurement equipment
  • Industrial laser applications
  • 3D printing and ATM machines
Model number
Power Out Max (W)
Input Voltage (VAC)
V1 Out Nom (V)
Output Current Max (A)
Cooling
DDP400-US12-VC
Power Out Max (W) 400
Input Voltage (VAC) 90 - 264
V1 Out Nom (V) 12
Output Current Max (A) 33.3
Cooling Fan
V2 Out (V)
12
I2 Out (A)
1
V3 Out (V)
5
I3 Out (A)
2
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to 50°C
Safety
UL60950-1, CSA C22.2 No. 60950-1: 2007, 2nd ed., EN60950-1 2nd ed., UL/IEC/EN 62368-1, CE
DDP400-US24-VC
Power Out Max (W) 400
Input Voltage (VAC) 90 - 264
V1 Out Nom (V) 24
Output Current Max (A) 16.7
Cooling Fan
V2 Out (V)
12
I2 Out (A)
1
V3 Out (V)
5
I3 Out (A)
2
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to 50°C
Safety
UL60950-1, CSA C22.2 No. 60950-1: 2007, 2nd ed., EN60950-1 2nd ed., UL/IEC/EN 62368-1, CE
DDP400-US36-VC
Power Out Max (W) 400
Input Voltage (VAC) 90 - 264
V1 Out Nom (V) 36
Output Current Max (A) 11.1
Cooling Fan
V2 Out (V)
12
I2 Out (A)
1
V3 Out (V)
5
I3 Out (A)
2
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to 50°C
Safety
UL60950-1, CSA C22.2 No. 60950-1: 2007, 2nd ed., EN60950-1 2nd ed., UL/IEC/EN 62368-1, CE
DDP400-US48-VC
Power Out Max (W) 400
Input Voltage (VAC) 90 - 264
V1 Out Nom (V) 48
Output Current Max (A) 8.3
Cooling Fan
V2 Out (V)
12
I2 Out (A)
1
V3 Out (V)
5
I3 Out (A)
2
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to 50°C
Safety
UL60950-1, CSA C22.2 No. 60950-1: 2007, 2nd ed., EN60950-1 2nd ed., UL/IEC/EN 62368-1, CE
Datasheets (PDF)
Datasheet - DDP400 Series

The fanned versions of the DDP400 series include a fan off condition under light load operation (<50W). This optimizes audible noise for fan cooled products to the lowest levels possible and maximizes fan lifetime, an ideal combination for audio and process control systems where power supplies are sized for short duration peak demand cycles. With typical efficiencies of 94% and efficiency load profiles that exceed 80 Plus Platinum requirements, the DDP400 is one of the most efficient power supplies in its class.