Skip to content

MDP1200-FF Front-Fan Medical Grade Power Supplies

The MDP1200-FF Front-fan Medical Grade power supplies offer high operating efficiency, 1U compatible form factors, and are equipped with built-in Digital Signal Processing (DSP) and PMBus™ communications protocols, for enhanced monitoring and control. The series offers 2x Mopp means of patient protection and BF apparatus compatibility.

Key features

  • Wide input voltage range 85 – 264 VAC
  • 1200 W rated power
  • 24 and 48 VDC standard output variants
  • High operating efficiency up to 94%
  • Low earth/touch leakage currents
    • <400 µA / <100 µA
  • +5V & +12V stand-by outputs
  • Built-in current sharing and OR-ing for parallel operation
  • 2x MoPP grade protection – BF apparatus compatible
  • 4000m altitude operation
  • Built-in DSP and PMBus™ communications protocols

Applications

  • MRI systems
  • Full-body tomography systems
  • Surgery room operating tables
  • Surgical dental chairs
  • X-ray medical equipment
  • Clinical / laboratory table-top / floor-based analyzers
  • Medical LED lighting
Model number
Power Out Max (W)
Input Voltage (VAC)
V1 Out Nom (V)
Output Current Max (A)
Cooling
MDP1200-US24-FF
Power Out Max (W) 1200
Input Voltage (VAC) 85 - 264
V1 Out Nom (V) 24
Output Current Max (A) 50
Cooling Fan-cooled
5VSB (A)
1
12VSB (A)
0.5
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to +70°C
Safety
IEC/EN 60601-1 3rd ed.; 2x MoPP - BF compatible: IEC/EN 60601-1-2 4th ed. EMC immunity, CE
Control & Monitoring
PMBus™, DSP
MDP1200-US48-FF
Power Out Max (W) 1200
Input Voltage (VAC) 85 - 264
V1 Out Nom (V) 48
Output Current Max (A) 25
Cooling Fan-cooled
5VSB (A)
1
12VSB (A)
0.5
Efficiency Rating (%)
94
Operating Altitude (m)
4000
Operating temperature range
-20 to 70°C
Safety
IEC/EN 60601-1 3rd ed, 2x MoPP - BF compatible: IEC/EN 60601-1-2 4th ed. EMC immunity, CE
Control & Monitoring
PMBus, DSP
Datasheets (PDF)
Datasheet - MDP1200 Series

The MDP1200-FF front-fan version of Medical Grade power supplies delivers a steady 1000 W over the full input voltage range of 85 – 264 VAC, or a steady 1200 W from 180 VAC and above input line voltage. This dual front-mounted fan version provides the full output rated load up to 60°C regardless of its orientation, which eases integration into power demanding systems. The dual fan rotation speed is digitally controlled to guarantee the minimum required airflow, minimizing audible noise, an unwanted factor in most medical environments. It is available in 24 and 48 VDC output variants.

The MDP1200 series are parallelable for redundant and/or higher power applications, facilitated by the internal OR-ing and current sharing functions. The series offers both analog and digital controls. Analog signals include DC Power-OK, PS-Inhibit, voltage adjustment, remote sense and current share controls. The digital control uses the standard PMBus™ protocol which allows communications and data logging between the power supply and system, and includes monitoring of input voltage, output voltages (+V1), output current (on +V1), current sharing, thermal health, fan health, life hours, power supply and status information. Additional alarm signals include fan fault, protections failure (OV, OC, OT) and voltages out of specifications. An LED provides visual indication of power supply status.

The MDP1200 series is approved to the 3rd edition of the ANSI/AAMI ES60601-1, IEC/EN 60601-1 standards for medical grade power supplies, including 2x MoPP means of patient protection and BF appliances compatibility, and complies with the EN 55011, EN 60601-1-2 Class B limits for conducted and radiated emissions, IEC/EN 61000-3 for harmonic and flicker, and IEC/EN 60601-1-2 4th edition for EMC immunity standards.