Skip to content

OPUS HE OC2066 Cabinet Power System

OPUS HE DC power systems are configurable and scalable, natural convection cooled, N+1 redundant backup power solutions designed to meet the demands of critical infrastructure applications.

Key features

  • Efficiency up to 97%
  • Fan Free – Natural convection cooled
  • Standard output voltages: 24, 48, 60, 110, 125 and 220 VDC
  • Scalable power from 1.5 kW to 24 kW, N+1 redundant
  • Configurable battery connections:
    • 1-3 strings
    • MCB
    • MCCB
    • Switch fuse protection
  • Configurable battery shelves and load distribution modules
  • Optional IP21 kit and drip cover
  • Optional IC cabinets and IP31 protection
  • EMC ratings:
    Cabinet: EN61439-1, EN61439-2
    Rectifiers: EN 61000-6-1 / -2 / -3 / -4 / -5
    EN50121-4 Rail, ETSI EN 300386 (48/60V)
  • Safety ratings:
    Cabinet: EN61439-1, EN61439-2
    Rectifiers: EN 62368-1, EN 50124-1 rail

Applications

  • Critical infrastructure
  • Transmission substations
  • Distribution substations
  • Railway signaling and substations
  • Process industries
  • Telecommunications
Model number
Power Out Max (kW)
Input Voltage (VAC)
Output Voltage Range (VDC)
Output Current Min (A)
Output Current Max (A)
OPUS HE 24-4.5 OC2066 F
Power Out Max (kW) 4.5
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 21 - 33
Output Current Min (A) 62.5
Output Current Max (A) 187.5
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 24-9.0 OC2066 F
Power Out Max (kW) 9.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 21 - 33
Output Current Min (A) 62.5
Output Current Max (A) 375
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 24-18.0 OC2066 F
Power Out Max (kW) 18.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 21 - 33
Output Current Min (A) 62.5
Output Current Max (A) 750
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
21
V1 Out Nom (V)
24
V1 Out Max (V)
33
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 48-6.0 OC2066 F
Power Out Max (kW) 6.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 42 - 59
Output Current Min (A) 41.7
Output Current Max (A) 125
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
42
V1 Out Nom (V)
48
V1 Out Max (V)
59
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 48-12.0 OC2066 F
Power Out Max (kW) 12.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 42 - 59
Output Current Min (A) 41.7
Output Current Max (A) 250
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
42
V1 Out Nom (V)
48
V1 Out Max (V)
59
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 48-24.0 OC2066 F
Power Out Max (kW) 24.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 42 - 59
Output Current Min (A) 41.7
Output Current Max (A) 500
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
42
V1 Out Nom (V)
48
V1 Out Max (V)
59
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 60-6.0 OC2066 F
Power Out Max (kW) 6.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 51 - 72
Output Current Min (A) 33.3
Output Current Max (A) 100
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
51
V1 Out Nom (V)
60
V1 Out Max (V)
72
Efficiency Rating (%)
97
Operating temperature range
-25 to 60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 60-12.0 OC2066 F
Power Out Max (kW) 12.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 51 - 72
Output Current Min (A) 33.3
Output Current Max (A) 200
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
51
V1 Out Nom (V)
60
V1 Out Max (V)
72
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 60-24.0 OC2066 F
Power Out Max (kW) 24.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 51 - 72
Output Current Min (A) 33.3
Output Current Max (A) 400
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
51
V1 Out Nom (V)
60
V1 Out Max (V)
72
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 110-6.0 OC2066 F
Power Out Max (kW) 6.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 90 - 150
Output Current Min (A) 18.5
Output Current Max (A) 55.5
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
90
V1 Out Nom (V)
110
V1 Out Max (V)
150
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 110-12.0 OC2066 F
Power Out Max (kW) 12.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 90 - 150
Output Current Min (A) 18.5
Output Current Max (A) 111
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
90
V1 Out Nom (V)
110
V1 Out Max (V)
150
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 110-24.0 OC2066 F
Power Out Max (kW) 24.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 90 - 150
Output Current Min (A) 18.5
Output Current Max (A) 222
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
90
V1 Out Nom (V)
110
V1 Out Max (V)
150
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 125-6.0 OC2066 F
Power Out Max (kW) 6.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 100 - 160
Output Current Min (A) 16.7
Output Current Max (A) 50
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
100
V1 Out Nom (V)
125
V1 Out Max (V)
160
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 125-12.0 OC2066 F
Power Out Max (kW) 12.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 100 - 160
Output Current Min (A) 16.7
Output Current Max (A) 100
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
100
V1 Out Nom (V)
125
V1 Out Max (V)
160
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 125-24.0 OC2066 F
Power Out Max (kW) 24.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 100 - 160
Output Current Min (A) 16.7
Output Current Max (A) 200
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
100
V1 Out Nom (V)
125
V1 Out Max (V)
160
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 220-6.0 OC2066 F
Power Out Max (kW) 6.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 178 - 280
Output Current Min (A) 18.5
Output Current Max (A) 27.8
Module Positions
3
Battery Shelves
1 - 4
V1 Out Min (V)
178
V1 Out Nom (V)
220
V1 Out Max (V)
280
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 220-12.0 OC2066 F
Power Out Max (kW) 12.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 178 - 280
Output Current Min (A) 18.5
Output Current Max (A) 55.5
Module Positions
6
Battery Shelves
1 - 4
V1 Out Min (V)
178
V1 Out Nom (V)
220
V1 Out Max (V)
280
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1
OPUS HE 220-24.0 OC2066 F
Power Out Max (kW) 24.0
Input Voltage (VAC) 400/230
Output Voltage Range (VDC) 178 - 280
Output Current Min (A) 18.5
Output Current Max (A) 111
Module Positions
12
Battery Shelves
1 - 4
V1 Out Min (V)
178
V1 Out Nom (V)
220
V1 Out Max (V)
280
Efficiency Rating (%)
97
Operating temperature range
-25 to +60°C
Cooling
Natural Convection
Control & Monitoring
VIDI+ Controller
Safety
EN61439-1, EN61439-2; Railway EN51024-1

OPUS HE power systems are robust backup power systems that deliver from 2 – 24 kW of output power at 48, 60, 110, 125 and 220 VDC, and from 1.5 – 18 kW at 24 VDC output. The cabinets have standard configurations for 3, 6 or 12 MHE rectifier modules, VIDI+ controllers, connections for mains and battery, and load distribution fuses or MCBs. Systems can easily be tailored to match unique application requirements by changing the quantity of rectifiers, battery fuses, battery shelves, load distribution and many other features.

In addition to 12 configurable relay alarms, systems can be remotely monitored via modern communication protocols such as Ethernet TCP/IP, Modbus TCP/IP, SCADA IEC61850, SNMP and RS-232.
OPUS HE power systems deliver up to 97% efficiency, are scalable from 1.5 kW to 24 kW, and are suitable for use in Power transmission substations, Power distribution substations, Railway signaling and substations, Process industries, and Telecommunications.

OPUS Battery Fuse Box
• Wall Mountable Fuse Box for Battery Installations
• Switch Fuse Protection
• Configurable Fuse Link
• Up to 125A

Datasheet – OPUS Battery Fuse Box

OPUS Battery Cabinet For Front Terminal Batteries
• 4 Battery shelves 320 x 530 x 595 mm
• User terminals 35 mm (8 pcs)
• Cable entry from top, neoprene cable glands (optional bottom cable entry)
• Adjustable legs

Datasheet – OPUS Battery Cabinet For Front Terminal Batteries

OPUS IC Battery Cabinets with Switch Fuse Protection
• Battery shelves for up to 4 x 48V/190Ah batteries
• Switch fuse protected battery strings (4 x 125A NH00 – fuse monitoring)
• Cable entry from top
• Ventilation output on the top
• Adjustable legs
• Strong welded structure
• Top lifting eyes

Datasheet – OPUS IC Battery Cabinets with Switch Fuse Protection